GENERAL
Capacity |
650VA |
Dimension (mm) |
286 x 96 x 138 (D x W x H) |
Weight (kg) |
4.3 |
INPUT
Voltage Range |
162 ~ 290VAC (Single boost)140 ~ 300VAC (Double boost) |
Frequency |
50Hz/60Hz (Auto-sensing) |
Phase |
Single + GND |
OUTPUT
Voltage Range |
220-240VAC |
Battery Mode |
220-240VAC |
Frequency |
50Hz ±1% (Battery mode) |
Waveform |
Simulated sine wave (Battery mode)Sine wave (AC mode) |
Transfer Time |
2ms typical |
BATTERY
Type |
12V/8.2AH x 1 |
Backup Time |
8 – 20 mins depending on load |
Recharge Time |
2-4 hours recover to 90% capacity |
INTERFACE & INDICATORS
Interface |
RS232, USB port, RJ45/RJ11 (Optional) |
Display |
LED/LCD Optional |
Alarm |
Batt. Mode, low battery, overload, fault, etc. |
PROTECTION/MONITORING
Short Circuit Protection |
Yes (Line mode & battery mode) |
Surge Protection |
Yes |
Alarm |
Audible & Visual |
Overload Protection |
Line mode : 100 – 120% 1 min change to fault mode
>120% change to fault mode immediatelyBattery mode : 100 – 120% 1 min change to fault mode
>120% change to fault mode immediately |
Intelligent Battery |
Prevent overcharging of battery |
Management |
Protect battery and prolong battery life |
Real Panel
1. AC Mode IndicatorGreen LED Lighting
2. Battery Mode Indicator
Battery Normal : Yellow LED Lighting and Blinking every 30s
Battery Low : Yellow LED Lighting and Blinking every 2s
3. Overload and Fault Indicator
Overload : Red LED Blinking every 2s
Fault : Red LED Lighting
4. Power Switch
5. Power AC Input
6. Backup Outlets |
GENERAL
Capacity |
650VA |
Dimension (mm) |
286 x 96 x 138 (D x W x H) |
Weight (kg) |
4.3 |
INPUT
Voltage Range |
162 ~ 290VAC (Single boost)140 ~ 300VAC (Double boost) |
Frequency |
50Hz/60Hz (Auto-sensing) |
Phase |
Single + GND |
OUTPUT
Voltage Range |
220-240VAC |
Battery Mode |
220-240VAC |
Frequency |
50Hz ±1% (Battery mode) |
Waveform |
Simulated sine wave (Battery mode)Sine wave (AC mode) |
Transfer Time |
2ms typical |
BATTERY
Type |
12V/8.2AH x 1 |
Backup Time |
8 - 20 mins depending on load |
Recharge Time |
2-4 hours recover to 90% capacity |
INTERFACE & INDICATORS
Interface |
RS232, USB port, RJ45/RJ11 (Optional) |
Display |
LED/LCD Optional |
Alarm |
Batt. Mode, low battery, overload, fault, etc. |
PROTECTION/MONITORING
Short Circuit Protection |
Yes (Line mode & battery mode) |
Surge Protection |
Yes |
Alarm |
Audible & Visual |
Overload Protection |
Line mode : 100 - 120% 1 min change to fault mode
>120% change to fault mode immediatelyBattery mode : 100 - 120% 1 min change to fault mode
>120% change to fault mode immediately |
Intelligent Battery |
Prevent overcharging of battery |
Management |
Protect battery and prolong battery life |
Real Panel
1. AC Mode IndicatorGreen LED Lighting
2. Battery Mode Indicator
Battery Normal : Yellow LED Lighting and Blinking every 30s
Battery Low : Yellow LED Lighting and Blinking every 2s
3. Overload and Fault Indicator
Overload : Red LED Blinking every 2s
Fault : Red LED Lighting
4. Power Switch
5. Power AC Input
6. Backup Outlets |
Custom Tab Content here.
Tail sed sausage magna quis commodo snasae. Aliquip strip steak esse ex in ham hock fugiat in. Labore velit pork belly eiusmod ut shank doner capicola consectetur landjaeger fugiat excepteur short loin. Pork belly laboris mollit in leberkas qui. Pariatur snasae aliqua pork chop venison veniam. Venison sed cow short loin bresaola shoulder cupidatat capicola drumstick dolore magna shankle.